4.4 Article

In vitro metabolic stability of obestatin: Kinetics and identification of cleavage products

期刊

PEPTIDES
卷 29, 期 10, 页码 1740-1748

出版社

ELSEVIER SCIENCE INC
DOI: 10.1016/j.peptides.2008.05.018

关键词

Obestatin metabolites; Peptide catabolism; Proteolytic activity; Cleavage sites; HPLC-PDA; Fluorescence; ESI-ion trap MS/MS; In vitro degradation of peptides; Protease inhibitors; Peptidomimetics

资金

  1. Flemish Institute [SBO-050164]

向作者/读者索取更多资源

The in vitro metabolic stability testing on synthetic obestatin peptides from two different species (human hOb and mouse mOb) using HPLC analysis is described. A reversed-phase C-18 column of 300 angstrom pore size was used, with a gradient system based on aqueous formic acid and acetonitrile. Electrospray ionization (ESI) ion trap mass spectrometry was used for identification of the chromatographic eluting peptide metabolic products, while UV (DAD) and fluorescence served quantitative purposes. Differences in the metabolic degradation kinetics of hob and mOb were found in plasma, liver and kidney homogenate, with half-lives ranging between 12.6 and 138.0 min. Proteolytic hydrolysis at the N-terminal Phe residue and cleavage at Pro(4)-Phe(5) were found to be two major metabolic pathways, accounting for more than 50% of the metabolic degradation. Several other labile peptide bonds were located. The influence of a standard protease inhibitor cocktail was investigated, as well as the metabolism of iodinated human obestatin in liver homogenate. Our results indicate that the major instability of obestatin peptides, as currently used in biomedical investigations, should be taken into account in the interpretation of the obtained results. (C) 2008 Elsevier Inc. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据