PEDIATRIC CRITICAL CARE MEDICINE
卷 13, 期 4, 页码 E255-E261出版社
LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/PCC.0b013e31823c98ef
关键词
cardiopulmonary bypass; centrifugation; extracorporeal membrane oxygenation; flow cytometry; hemolysis; platelet aggregates
资金
- Teh Shah Memorial ECMO
- Children's National Board of Lady Visitors
Objective: A state-of-the-art centrifugal pump combined with hollow-fiber oxygenator for extracorporeal membrane oxygenation has potential advantages such as smaller priming volumes and decreased potential to cause tubing rupture as compared with the traditional roller head/silicone membrane systems. Adoption of these state-of-the-art systems has been slow in neonates as a result of past evidence of severe hemolysis that may lead to renal failure and increased mortality. Extracorporeal systems have also been linked to platelet dysfunction, a contributing factor toward intracranial hemorrhage, a leading cause of infant morbidity. Little data exist comparing the centrifugal systems with the roller systems in terms of hemolysis and platelet aggregation at low flow rates commonly used in neonatal extracorporeal membrane oxygenation. Design: Prospective, comparative laboratory study. Setting: University research laboratory. Subjects: Centrifugal pump, roller pump, hollow-fiber oxygenator, and silicone membrane oxygenator. Interventions: Comparative study using two pumps, the centrifugal Jostra Rotaflow (Maquet, Wayne, NJ) and the roller-head (Jostra, Maquet, Wayne, NJ), and two oxygenators, polymethlypentene Quadrox-D (Maquet) and silicone membrane (Medtronic, Minneapolis, MN). Five test runs of four circuit combinations were examined for hemolysis and platelet aggregation during 6 hrs of continuous use in a simulated in vitro extracorporeal membrane oxygenation circuit circulating whole swine blood at 300 mL/min. Measurements and Main Results: Hemolysis was assessed by spectrophometric measurement of plasma-free hemoglobin. Platelet aggregation was evaluated using monoclonal CD61 antibody fluorescent flow cytometry profiles. All of the extracorporeal membrane oxygenation systems created plasma-free hemoglobin at a similar rate compared with static blood control. There was no difference in the mean normalized index of hemolysis of the centrifugal/-hollow-fiber oxygenator system as compared with the roller-head/silicone membrane systems (0.0032 g/100 L vs. 0.0058 g/100 L, p = .7). None of the extracorporeal membrane oxygenation systems had a significant increase in platelet aggregation above baseline. Conclusions: In a low-flow neonatal environment, a state-of-the-art centrifugal pump combined with new fiber-type oxygenators appear to be safe in regard to hemolysis and platelet aggregation. (Pediatr Crit Care Med 2012; 13:e255-e261)
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐
暂无数据