4.3 Article

Sensitive and rapid detection of Paragonimus westermani infection in humans and animals by loop-mediated isothermal amplification (LAMP)

期刊

PARASITOLOGY RESEARCH
卷 108, 期 5, 页码 1193-1198

出版社

SPRINGER
DOI: 10.1007/s00436-010-2162-x

关键词

-

资金

  1. National ST Major Program [2008ZX10004-011]
  2. National Key Technology RD Program [2008BAI56B03]
  3. State Key Laboratory of Veterinary Etiological Biology, Lanzhou Veterinary Research Institute, Chinese Academy of Agricultural Sciences

向作者/读者索取更多资源

In the present study, a loop-mediated isothermal amplification (LAMP) assay was developed and validated for the detection of Paragonimus westermani adults, metacercariae, and eggs in human and animal samples. The LAMP amplification can be finished in 45 min under isothermal condition at 60A degrees C by employing a set of four species-specific primer mixtures and the results can be checked by naked-eye visualization. No amplification products were detected with deoxyribunucleic acid (DNA) of related trematode species including Fasciola hepatica, Fasciola gigantica, Clonorchis sinensis, Opisthorchis viverrini, Schistosoma mansoni, and Schistosoma japonicum. The method was further validated by examining P. westermani DNA in intermediate hosts including freshwater crabs and crayfish, as well as in sputum and pleural fluid samples from patients of paragonimiasis. These results indicated that the LAMP assay was highly specific, sensitive, and rapid, and it was approximately 100 times more sensitive than conventional specific PCR. The LAMP assay established in this study provides a rapid and sensitive tool for the detection of P. westermani DNA in freshwater crabs, crayfish, sputum, and pleural fluid samples, which has important implications for effective control of human paragonimiasis.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据