期刊
TRANSACTIONS OF THE CANADIAN SOCIETY FOR MECHANICAL ENGINEERING
卷 39, 期 3, 页码 739-748出版社
CSME TRANS
DOI: 10.1139/tcsme-2015-0059
关键词
LEDs; aluminum-acetone flat plate heat pipe; cooling module
资金
- National Science Council of Taiwan [NSC102-2221-E-024-010, MOST103-2221-E-269-007, NSC 102-2632-E-035-001-MY3]
It is well known that heat generation will be harmful to high power LEDs. It is hardly effectively dissipated and results in a serious problem in the luminous efficiency. The most important issue in LED research is to find a potential design of heat removal. The purpose of this study is to design the LEDs combined with the cooling module of the aluminum-acetone flat plate heat pipe by the experimental and numerical simulation for obtaining high efficiency in heat removal. The high power LEDs with and without heat pipe cooling module are compared. The numerical simulation is built and agrees with the experiment. The heat removal efficiency of the cooling module reaches 92.09% and drops the junction temperature of LED about 36 degrees C. This cooling module has proven to be effective in solving the heat concentration problems associated with the LED chips. In short, the phase change cooling module will apply on the electronic component of high heat concentration for more effective cooling method.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐
暂无数据