4.1 Article

Comparative Study of Lens Solutions' Ability to Remove Tear Constituents

期刊

OPTOMETRY AND VISION SCIENCE
卷 91, 期 9, 页码 1045-1061

出版社

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/OPX.0000000000000340

关键词

silicone hydrogel contact lens; tear film; deposition; atomic force microscopy; cleaning solution

资金

  1. Natural Sciences and Engineering Research Council of Canada
  2. Canadian Foundation for Innovation
  3. Ontario Research Fund
  4. University of Waterloo
  5. Abbott Medical Optics
  6. Advanced Vision Research
  7. Alcon
  8. AlgiPharma
  9. Allergan
  10. Bausch + Lomb
  11. CIBA Vision
  12. CooperVision
  13. Essilor
  14. Johnson & Johnson Vision Care
  15. Oculus
  16. TearScience
  17. Visioneering Technologies

向作者/读者索取更多资源

Purpose. The purpose of this study was to use atomic force microscopy to compare and characterize the cleaning abilities of a hydrogen peroxide-based system (HPS) and a polyhexamethylene biguanide-containing multipurpose solution (MPS) at removing in vitro deposited tear film constituents, as well as to determine deposition patterns on various silicone hydrogel contact lenses. Methods. Silicone hydrogel materials-balafilcon A (BA), lotrafilcon B (LB), and senofilcon A (SA)-were incubated for 1 week in an artificial tear solution (ATS) containing representative lipids, proteins, and salts from the tear film. Atomic force microscopy was used to resolve each lens before and after being cleaned overnight in HPS or MPS. Atomic force microscopy was used again to resolve HPS/MPS-cleaned lenses, which were reincubated in fresh ATS for 1 week, before and after an overnight clean in their respective cleaning solution. Results. Atomic force microscopy imaging was able to characterize lens deposits with high resolution. Lenses incubated in ATS revealed distinct differences in their deposition pattern across lens materials. The surface of BA contained about 20-nm-high deposits, whereas deposit heights up to 150 nm completely occluded the surface of SA. Lotrafilcon B lenses revealed clusters of deposits up to 90 nm. The use of either lens solution left trace amounts of tear film constituents, although components from the MPS were seen adsorbed onto the surface after cleaning. Surface roughness (R-a) measurements revealed a significant difference between ATS-incubated and HPS/MPS-cleaned SA and LB lenses (p < 0.05). R-a between first incubated and HPS/MPS-cleaned reincubated SA and LB was also significant (p < 0.05). Conclusions. Unique variations in ATS deposition patterns were seen between lenses with atomic force microscopy. The application of both HPS and MPS removed most visible surface deposits.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.1
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据