4.1 Article Proceedings Paper

Performance of Wavefront-Guided Soft Lenses in Three Keratoconus Subjects

期刊

OPTOMETRY AND VISION SCIENCE
卷 85, 期 12, 页码 1172-1178

出版社

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/OPX.0b013e31818e8eaa

关键词

keratoconus; Zernike; wavefront; wavefront-guided; soft contact lens; rigid contact lens; aberration

资金

  1. NEI NIH HHS [P30 EY07551-UHCO, R01 EY008520-13, R01 EY008520, P30 EY007551-169001, T32 EY07024, T32 EY007024, P30 EY007551, R01 EY08520] Funding Source: Medline

向作者/读者索取更多资源

Purpose. To examine whether custom wavefront-guided soft contact lenses provide visual and optical performance equivalent to habitual gas permeable (GP) corrections in three keratoconus subjects. Methods. Custom wavefront-guided soft contact lenses were produced and evaluated at the Visual Optics Institute, College of Optometry, University of Houston for three habitual GP-wearing keratoconus subjects. Photopic high and mesopic low contrast logarithm of minimum angle of resolution visual acuity (logMAR VA) and residual second to tenth order optical aberrations experienced with these custom soft lenses were recorded and compared with the subjects' habitual GP correction. Results. All three subjects wearing custom soft lenses reached the established exit criterion of photopic high contrast (HC) logMAR VA equal to or better than values recorded with their habitual GP lens. HC logMAR VA for GP and custom soft lens correction was 0.01 +/- 0.05 and 0.00 +/- 0.02 for KC1, 0.20 +/- 0.02 and 0. 14 +/- 0.02 for KC2, and 0.04 +/- 0.09 and -0.05 +/- 0.05 for KC3, respectively. In addition, KC2 reached the exit criterion of high-order aberration levels equal to or less than values with their habitual GP lens (GP lens: 0.394 +/- 0.024 mu m, custom lens: 0.381 +/- 0.074 mu m). Conclusions. Custom wavefront-guided soft contact lenses have been demonstrated to provide equivalent photopic HC logMAR VA to that achieved with habitual GP correction in three keratoconus subjects. Future emphasis will be placed on surpassing habitual GP performance and reaching a normal age-matched criterion for both VA and aberration measures. Achieving these goals may require a more thorough understanding of the relationship between visual performance and residual aberration experienced during custom lens wear through the use of image quality metrics predictive of visual performance.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.1
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据