期刊
OPTICS LETTERS
卷 35, 期 9, 页码 1419-1421出版社
OPTICAL SOC AMER
DOI: 10.1364/OL.35.001419
关键词
-
类别
资金
- National Institutes of Health (NIH) [R01 EB000712, R01 NS46214, R01 EB008085, R01 CA113453901, U54 CA136398, 5P60 DK02057933]
- Microphotoacoustics, Inc.
- Endra, Inc.
- NATIONAL CANCER INSTITUTE [R01CA134539, U54CA136398] Funding Source: NIH RePORTER
- NATIONAL INSTITUTE OF BIOMEDICAL IMAGING AND BIOENGINEERING [R01EB000712, R01EB008085] Funding Source: NIH RePORTER
- NATIONAL INSTITUTE OF NEUROLOGICAL DISORDERS AND STROKE [R01NS046214] Funding Source: NIH RePORTER
A method is proposed to measure transverse blood flow by using photoacoustic Doppler broadening of bandwidth. By measuring bovine blood flowing through a plastic tube, the linear dependence of the broadening on the flow speed was validated. The blood flow of the microvasculature in a mouse ear and a chicken embryo (stage 16) was also studied. (C) 2010 Optical Society of America
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐
暂无数据