- Natural Sciences and Engineering Research Council of Canada
- Fonds de Recherche du Quebec - Nature et Technologies
We demonstrate a generalized method for dual-comb interferometry that involves the use of two frequency combs with quasi-integer-ratio repetition rates. We use a 16.67 MHz comb to probe an 80-cm-long ring cavity and a 100 MHz comb to asynchronously sample its impulse response. The resulting signal can be seen as six time-multiplexed independent interferograms. We perform a deconvolution of the photodetector's impulse response to prevent any crosstalk between these multiplexed data sets. The measurement is then demultiplexed and corrected with referencing signals. We obtain a measurement with a spectral point spacing of 16.67 MHz and a spectral SNR of 55 dB by averaging 15,000 interferograms, corresponding to a measurement time of 500 s. Compared to conventional dual-comb spectroscopy, this generalized technique allows to either reduce the spectral point spacing or the acquisition time by changing the repetition rate of only one of the combs. (C) 2014 Optical Society of America