Purpose: To measure choroidal thickness and to determine parameters associated with it. Design: Cross-sectional study. Participants: Seventy-four glaucoma patients and glaucoma suspects. Methods: Spectral domain optical coherence tomography (SD-OCT) scans were obtained to estimate average choroidal thickness in a group of glaucoma suspects and glaucoma patients. The average thickness was calculated from enhanced depth SD-OCT images and manually analyzed with Image J software. Open-angle glaucoma, open-angle glaucoma suspect, primary angle-closure glaucoma, primary angle closure, and primary angle-closure suspect were defined by published criteria. Glaucoma suspects had normal visual fields bilaterally. Glaucoma was defined by specific criteria for optic disc damage and visual field loss in >= 1 eye. The most affected eye was analyzed for comparisons across individuals, and right/ left and upper half/lower half comparisons were made to compare thickness against degree of visual field damage. Main Outcome Measures: Average macular and peripapillary choroidal thickness measured using SD-OCT. Results: The choroidal-scleral interface was visualized in 86% and 96% of the macular and peripapillary scans, respectively. In multivariable linear regression analysis, the macular choroid was significantly thinner in association with 4 features: Longer eyes (22 mu m per mm longer [95% confidence interval (CI), -33, -11]), older individuals (31 mu m thinner per decade older [95% CI, -44, -17]), lower diastolic ocular perfusion pressure (26 mu m thinner per 10 mmHg lower [95% CI, 8, 44]), and thicker central corneas (6 mu m per 10 mu m thicker cornea [95% CI, -10, 0]). The choroid was not significantly thinner in glaucoma patients than in suspects (14 mu m [95% CI, -54, 26]; P = 0.5). Peripapillary choroidal thickness was not significantly different between glaucoma and suspect patients. Thickness was not associated with damage severity as estimated by visual field mean deviation or nerve fiber layer thickness, including comparisons of right with left eye or upper with lower values. Conclusions: Age, axial length, CCT, and diastolic ocular perfusion pressure are significantly associated with choroidal thickness in glaucoma suspects and glaucoma patients. Degree of glaucoma damage was not consistently associated with choroidal thickness. Financial Disclosure(s): Proprietary or commercial disclosure may be found after the references. Ophthalmology 2011; 118: 1571-1579 (C) 2011 by the American Academy of Ophthalmology.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据