Average 3-Dimensional Models for the Comparison of Orbscan II and Pentacam Pachymetry Maps in Normal Corneas

期刊

OPHTHALMOLOGY
卷 116, 期 11, 页码 2064-2071

出版社

ELSEVIER SCIENCE INC
DOI: 10.1016/j.ophtha.2009.04.036

关键词

-

资金

  1. Canadian Institutes for Health Research, Ottawa, Canada
  2. FRSQ Research in Vision Network, Montreal. Canada
  3. Fonds France Canada pour la Recherche (FFCR)

向作者/读者索取更多资源

Purpose: To assess the reliability of Orbscan (Bausch & Lomb, Salt Lake City, UT) and Pentacam (Oculus, Wetzlar, Germany) central corneal thickness (CCT) and peripheral corneal thickness (PCT) measurements based on 2 methodologies. Design: Evaluation of a diagnostic technology. Participants: Thirty healthy volunteers were recruited prospectively at the Department of Ophthalmology of the Hotel-Dieu Hospital, Paris, France. Methods: Central corneal thickness and PCT were assessed, using ultrasound pachymetry (USP) as the gold standard. Two methodologies were used: (1) the traditional analysis of pachymetry data from 1 central and 8 peripheral reference positions on the cornea, and (2) a 3-dimensional (3-D) analysis based on average corneal pachymetry maps constructed for each system (Orbscan, Pentacam, and USP), each operator (operators 1 and 2), and each visit (visits A and B). Main Outcome Measures: Repeatability, intersystem reproducibility, interoperator reproducibility, reproducibility over time, and accuracy of Orbscan and Pentacam CCT and PCT measurements. Distribution and statistical significance of the differences between 3-D average maps. Results: Repeatability (Orbscan intraclass correlation coefficients [ICCs], 0.967-0.992; Pentacam ICCs, 0.986-0.997), interoperator reproducibility, and reproducibility over time (ICCs, 0.976-0.997) were excellent to almost perfect for both systems. Intersystem agreement was almost perfect for CCT (ICC, 0.980), but less strong for PCT (ICCs, 0.928-0.979). Despite a good to excellent agreement between the optical systems and USP (ICCs, 0.608-0.958), LISP CCT readings were thicker (mean difference, up to 15.2 mu m; P<0.05), and LISP PCT readings were thinner (P<0.05). Orbscan and Pentacam average maps allowed comprehensive interpretation of differences between populations according to the magnitude, distribution, and statistical significance, minimizing the risk of giving excessive weight to few data measured at specific locations on the cornea. Conclusions: Both methodologies showed that Orbscan and Pentacam CCT readings are interchangeable, whereas caution should be used for PCT readings. Interchangeability with USP measurements also was shown to be limited. The high repeatability, interoperator reproducibility, reproducibility over time, the extent of the information generated by a single capture, and the noncontact nature of the Orbscan and Pentacam all suggest that optical systems eventually may replace LISP as the gold standard for corneal pachymetry. Financial Disclosure(s): The author(s) have no proprietary or commercial interest in any materials discussed in this article. Ophthalmology 2009; 116:2064-2071 (C) 2009 by the American Academy of Ophthalmology.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据