4.6 Article Proceedings Paper

Exposure rate of hydroxyapatite orbital implants

期刊

OPHTHALMOLOGY
卷 115, 期 3, 页码 566-572

出版社

ELSEVIER SCIENCE INC
DOI: 10.1016/j.ophtha.2007.06.014

关键词

-

向作者/读者索取更多资源

Objective: To document the long-term experience with hydroxyapatite (HA) orbital implants (Bio-Eye) and analyze the factors influencing implant exposure, including surgical type, procedural modification, use of different wrapping materials and peg materials. Design: Retrospective observational case series. Participants: Eight hundred two eyes from 802 patients who underwent anophthalmic socket surgery (eviscerations, enucleations, secondary implant placements) using HA implants, performed by one surgeon between May 1990 and December 2005. Methods: All patients' clinical records were reviewed. Baseline age, cause of anophthalmic surgery, surgical type, size of HA implant, wrapping material, and peg system were recorded. Main Outcome Measures: Postoperative complications, especially implant exposure, were recorded separately before and after pegging, and compared according to type of surgery, wrapping material, and peg system. Results: The main cause of anophthalmic surgery was trauma (73%). A Variety of wrapping materials have been used, including Tutoplast-dura, Vicryl mesh, autogenous sclera, and polyester-urethane. Implant exposure occurred in 17 patients (2.1%) before pegging and 14 (4.0%) after pegging. The exposure rate was significantly higher in eyes eviscerated without (7.2%) than with (1.1%) keratectomy (P = 0.018), but did not differ according to type of surgery (P = 0.710). When distributed according to 5-year periods, the exposure rate was higher from 1990 to 1994 (4.7%) than in later periods (P = 0.004). In patients who underwent enucleation or secondary implantation, there was no difference in exposure rate between Tutoplast-dura- and Vicryl mesh-wrapped implants (P = 0.235). Among the 353 patients (44.0%) who underwent pegging, those who received titanium-pegged implants had a significantly lower incidence of peg extrusion (5.2%), major discharge (5.2%), and pyogenic granuloma (9.1 %) than those with non-sleeved polymethyl methacrylate and sleeved polycarbonate peg materials (P < 0.05). Conclusions: Exposures associated with HA orbital implants decreased with the improvement of surgical technique over time and have been managed successfully, both before and after pegging. The incidence of peg-related complications have decreased since the introduction of the titanium peg system.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据