The metal-organic framework HKUST-1 as efficient sorbent in a vortex-assisted dispersive micro solid-phase extraction of parabens from environmental waters, cosmetic creams, and human urine

期刊

TALANTA
卷 139, 期 -, 页码 13-20

出版社

ELSEVIER
DOI: 10.1016/j.talanta.2015.02.032

关键词

Metal-organic frameworks; Dispersive solid-phase extraction; Micro-solid-phase extraction; Parabens; Personal care products; Vortex-assisted methods; Environmental waters; Cosmetic creams; Human urine

资金

  1. Spanish Ministry of Economy and Competitiveness (MINECO)
  2. University of La Laguna (ULL)
  3. MINECO, Spain [MAT2013-43101-R]
  4. Fundacion CajaCanarias [SPDs-AGUA05]
  5. MINECO [MAT2010-16981]
  6. ULL-International Excellence Campus (CEI)
  7. ULL [MAT2010-16981]
  8. Canary Agency for Research and Innovation (ACIISI)

向作者/读者索取更多资源

Three metal-organic frameworks (MOFs), specifically HKUST-1, MOF-5, and MIL-53(AI), have been synthetized, characterized, studied and compared in a vortex-assisted dispersive micro-solid-phase extraction (VA-D-mu-SPE) procedure in combination with high-performance liquid chromatography (HPLC) with diode-array detection (DAD) for determining seven parabens in environmental waters (tap water, swimming pool water, and water coming from a spa pool), human urine (from two volunteers), and cosmetic creams (two commercial brands). Experimental parameters, such as nature and amount of MOF, sample volume, nature of elution solvent and its amount, vortex and centrifugation time, among others, were properly optimized. HKUST-1 was the most adequate MOF to work with. Detection limits for the overall method down to 0.1 mu g L-1 for butylparaben (BPB) and benzylparaben (BzPB) were obtained, with determination coefficients (R-2) higher than 0.9966 for a range of 0.5-147 mu g L-1 (depending on the paraben), average relative recoveries (RR, in %) of 803% at the low spiked level (7 mu g L-1), and relative standard deviation (RSD) values below 10% also at the low spiked level. The strength of the affinity between HKUST-1 and parabens was evaluated, and it ranged from 33.5% for isopropylparaben (iPPB) to 77.0% for isobutylparaben (iBPB). When analyzing complex environmental waters, RR values of 78%, inter-day precision values (as RSD) lower than 15%, and intra-day precision values lower than 7.8% were obtained, despite the observed matrix effect. When analyzing cosmetic creams, parabens were detected, with contents ranging from 0.14 +/- 0.01 mu g g(-1) for EPB in the healing cream analyzed to 1.12 +/- 0.07 mg g(-1) for MPB in the mask cream analyzed, with precision values (RSD) lower than 12% and RR values from 63.7% for propylparaben (PPB) to 121% for iPPB. When analyzing human urine, no parabens were detected but the method could be performed with RSD values lower than 19%. These results show the adequateness of MOFs as sorbents in VA-D-mu-SPE procedures despite sample complexity. (C) 2015 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据