4.7 Article

Performance of metal-organic framework MIL-101 after surfactant modification in the extraction of endocrine disrupting chemicals from environmental water samples

期刊

TALANTA
卷 143, 期 -, 页码 366-373

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.talanta.2015.05.006

关键词

MIL-101; Surface modification; Triton X-114; Dispersive solid-phase extraction; Endocrine disrupting chemicals

资金

  1. Singapore National Research Foundation under its Environmental & Water Technologies Strategic Research Program [R143-000-438-272]
  2. National University of Singapore
  3. EWI

向作者/读者索取更多资源

The research presented in this paper explored the modification and application of a metal-organic framework, MIL-101, with nonionic surfactant-Triton X-114 in dispersive solid-phase extraction for the preconcentration of four endocrine disrupting chemicals (estrone, 17 alpha-ethynylestradiol, estriol and diethylstilbestrol) from environmental water samples. Triton X-114 molecules could be adsorbed by the hydrophobic surface of the MIL-101 crystals, and thus improved the dispersibility of MIL-101 in aqueous solution by serving as a hydrophilic coating. Cloud point phase separation from Triton X-114 accelerated the separation of extracts from the aqueous matrix. The proposed method combines the favorable attributes of strong adsorption capacity resulting from the porous structure of MIL-101 and self-assembly of Triton X-114 molecules. Post-extraction derivatization using N-methyl-N-(trimethylsilyl)trifluoroacetamide was employed to facilitate the quantitative determination of the extracts by gas chromatography-mass spectrometry. The main factors affecting the preparation of modified MIL-101, and extraction of the analytes, such as the amount of surfactant, the ultrasonic and vortex durations, solution pH and desorption conditions, were investigated in detail. Under the optimized conditions, the present method yielded low limits of detection (0.006-0.023 ng/mL), good linearity from 0.09 to 45 ng/mL (coefficients of determination higher than 0.9980) and acceptable precision (relative standard deviations of 2.2-13%). The surface modified MIL-101 was demonstrated to be effective for the extraction of the selected estrogens from aqueous samples, giving rise to markedly improved extraction performance compared to the unmodified MIL-101. (C) 2015 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据