4.4 Article

A novel HPGe detector for gamma-ray tracking and imaging

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.nima.2011.10.008

关键词

HPGe detector; Gamma-ray tracking; Position sensitivity; Gamma-ray imaging

资金

  1. U.S. Department of Energy Office of Science, Office of Nuclear Physics
  2. U.S. Department of Energy

向作者/读者索取更多资源

A novel, large-volume High Purity Germanium (HPGe) detector that will provide gamma-ray detection with both sub-mm position resolution and high efficiency is under development. This design is based on a coaxial HPGe geometry and employs a point contact along with segmentation of the outer electrode. Calculations indicate that this device will be capable of achieving values of position sensitivity which are approximately a factor of four or five greater than conventional gamma-ray tracking detectors. (C) 2011 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据