期刊
出版社
ELSEVIER SCIENCE BV
DOI: 10.1016/j.nima.2009.10.101
关键词
Ultra-cold neutrons; Neutron guides; Transmission; UCN detection
类别
资金
- DFG Cluster of Excellence
The efficient transport of ultra-cold neutrons (UCN) from their source to the experimental site is a major issue for various kinds of precision experiments. Neutron guides often have to transport the UCN several tens of meters with acceptable losses. In order to qualify the guides, their UCN transmission properties have to be determined with high precision. For this purpose we have developed a novel method. The transmitted UCN were absorbed at the end of the guide in a vanadium disc producing the beta-emitter V-52 (half life 3.74 min). The intensity of the 1434 keV gamma-ray following the P-decay was measured. UCN guides of non-magnetic nickel alloys made by the replication technique were studied. They show a high Fermi pseudopotential V-F for UCN and a low surface roughness. For these guides the transmission per meter was determined with a relative error of +/- 0.6%, resulting in values above 0.95/m. By an absolute calibration of the gamma-ray detection system we also deduced the absolute value of the UCN current absorbed in the vanadium plate. Possible applications of this method are discussed. (C) 2009 Elsevier B.V. All rights reserved.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐
暂无数据