期刊
出版社
ELSEVIER SCIENCE BV
DOI: 10.1016/j.nima.2008.08.018
关键词
Particle identification; Aerogel; Time resolution; Cosmic tests
类别
资金
- [School-5655.2008.2]
- [RFBR 08-02-00328-a]
- [08-02-00634-a]
- [08-02-00660-a]
- [07-02-00104-a]
- [06-02-16192-a]
- [06-02-16273-a]
- [06-02-16294-a]
The paper is devoted to the cosmic tests of particle identification system for the SND detector at VEPP-2000. The goal of the tests is to measure main parameters of the system: average signal for the relativistic particles, nonuniformity of the light collection, and time resolution. The measurements of the average signal were done in five points of the counter. The obtained value of the signal is about 10 photoelectrons. The time resolution is about 2 ns. The time dependence of the average amplitude was measured also. It was shown that average amplitude of the signal decreases with characteristic time of about two years. The cause of the signal decrease is discussed. (C) 2008 Elsevier BY. All rights reserved.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐
暂无数据