4.8 Article

Reduction in Inappropriate Therapy and Mortality through ICD Programming

期刊

NEW ENGLAND JOURNAL OF MEDICINE
卷 367, 期 24, 页码 2275-2283

出版社

MASSACHUSETTS MEDICAL SOC
DOI: 10.1056/NEJMoa1211107

关键词

-

资金

  1. Boston Scientific
  2. University of Rochester
  3. Guidant
  4. Lundbeck
  5. Gilead
  6. Zoll
  7. Medtronic
  8. Sanofi-Aventis
  9. Premier
  10. Biotronik
  11. Cameron Health
  12. Executive Health Resources
  13. Boehringer Ingelheim
  14. Amarin
  15. BioControl
  16. Network for Continuing Medical Education
  17. St. Jude Medical

向作者/读者索取更多资源

BACKGROUND The implantable cardioverter-defibrillator (ICD) is highly effective in reducing mortality among patients at risk for fatal arrhythmias, but inappropriate ICD activations are frequent, with potential adverse effects. METHODS We randomly assigned 1500 patients with a primary-prevention indication to receive an ICD with one of three programming configurations. The primary objective was to determine whether programmed high-rate therapy (with a 2.5-second delay before the initiation of therapy at a heart rate of >= 200 beats per minute) or delayed therapy (with a 60-second delay at 170 to 199 beats per minute, a 12-second delay at 200 to 249 beats per minute, and a 2.5-second delay at >= 250 beats per minute) was associated with a decrease in the number of patients with a first occurrence of inappropriate antitachycardia pacing or shocks, as compared with conventional programming (with a 2.5-second delay at 170 to 199 beats per minute and a 1.0-second delay at >= 200 beats per minute). RESULTS During an average follow-up of 1.4 years, high-rate therapy and delayed ICD therapy, as compared with conventional device programming, were associated with reductions in a first occurrence of inappropriate therapy (hazard ratio with high-rate therapy vs. conventional therapy, 0.21; 95% confidence interval [CI], 0.13 to 0.34; P < 0.001; hazard ratio with delayed therapy vs. conventional therapy, 0.24; 95% CI, 0.15 to 0.40; P < 0.001) and reductions in all-cause mortality (hazard ratio with high-rate therapy vs. conventional therapy, 0.45; 95% CI, 0.24 to 0.85; P = 0.01; hazard ratio with delayed therapy vs. conventional therapy, 0.56; 95% CI, 0.30 to 1.02; P = 0.06). There were no significant differences in procedure-related adverse events among the three treatment groups. CONCLUSIONS Programming of ICD therapies for tachyarrhythmias of 200 beats per minute or higher or with a prolonged delay in therapy at 170 beats per minute or higher, as compared with conventional programming, was associated with reductions in inappropriate therapy and all-cause mortality during long-term follow-up. (Funded by Boston Scientific; MADIT-RIT ClinicalTrials.gov number, NCT00947310.)

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据