Radiation exposure during scoliosis surgery: a prospective study

期刊

SPINE JOURNAL
卷 15, 期 3, 页码 33S-36S

出版社

ELSEVIER SCIENCE INC
DOI: 10.1016/j.spinee.2014.12.149

关键词

Scoliosis surgery; Radiation exposure; Children; Surgeon; Cancer risk; Radiation protection

向作者/读者索取更多资源

BACKGROUND CONTEXT: The present literature on the cancer risks related to radiation exposure in patients and surgeons during scoliosis surgery is sparse. PURPOSE: To assess the radiation exposure in patients and surgeons during scoliosis surgery and estimate the increased cancer risk of both groups. STUDY DESIGN: Over a 6-month period, we conducted a prospective study to monitor the intra-operative radiation dose received by both patients and surgeons during scoliosis cases. PATIENT SAMPLE: It included 30 consecutive patients undergoing scoliosis surgery by a team of two surgeons (S1 and S2). OUTCOME MEASURES: We measured the radiation exposure to the eyes, thyroid, and hands for each surgeon; measured the difference of radiation exposure between the two surgeons; the difference in radiation exposure with respect to the proximity of the surgeon to the X-ray tube, and the radiation exposure for each patient. METHODS: An electronic dosimeter was attached over the thyroid guard and a thermoluminescent dosimeter ring on both hands of each surgeon. The patients were monitored using the dose area product (DAP) measurements from the image intensifier, and their radiation exposure was calculated with the Monte Carlo calculation. RESULTS: The mean eye dose per procedure for the two surgeons S1 and S2 was 0.8 mu Sv and 1.3 mSv, respectively. The mean thyroid dose for S2 and S1 was 1.2 mu Sv and 1.4 mu Sv, respectively. The dose recorded by the surgeon on the same side of the patient as the X-ray tube was significantly higher than for the surgeon on the far side (p<.05). Mean DAP per procedure was 91.3 cGycm(2) and the mean radiation dose for patients was 252.9 mu Sv. The increase in cancer risk for patients and surgeons was 0.001% and 0.0005%, respectively, for each year of exposure. CONCLUSIONS: A significantly higher dose of radiation during scoliosis surgery was received by the surgeon standing on the same side as the X-ray tube. However, both surgeons received a total radiation dose of less than 1% of the recommended dose limit per year and, therefore, the total radiation exposure in both surgeons and patients was well within the recommended safe limits. (C) 2015 Elsevier Inc. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据