4.7 Article

Removing artefacts from TMS-EEG recordings using independent component analysis: Importance for assessing prefrontal and motor cortex network properties

期刊

NEUROIMAGE
卷 101, 期 -, 页码 425-439

出版社

ACADEMIC PRESS INC ELSEVIER SCIENCE
DOI: 10.1016/j.neuroimage.2014.07.037

关键词

Transcranial magnetic stimulation; Electroencephalography; Independent component analysis; Artefacts; Dorsolateral prefrontal cortex; Motor cortex

资金

  1. National Health and Medical Research Council (NHMRC) of Australia [607223, 1072057]
  2. NHMRC

向作者/读者索取更多资源

Introduction: The combination of transcranial magnetic stimulation and electroencephalography (TMS-EEG) is emerging as a powerful tool for causally investigating cortical mechanisms and networks. However, various artefacts contaminate TMS-EEG recordings, particularly over regions such as the dorsolateral prefrontal cortex (DLPFC). The aim of this study was to substantiate removal of artefacts from TMS-EEG recordings following stimulation of the DLPFC and motor cortex using independent component analysis (ICA). Methods: 36 healthy volunteers (30.8 +/- 9 years, 9 female) received 75 single TMS pulses to the left DLPFC or left motor cortex while EEG was recorded from 57 electrodes. A subset of 9 volunteers also received 50 sham pulses. The large TMS artefact and early muscle activity (-2 to similar to 15 ms) were removed using interpolation and the remaining EEG signal was processed in two separate ICA runs using the FastICA algorithm. Five sub-types of TMS-related artefacts were manually identified: remaining muscle artefacts, decay artefacts, blink artefacts, auditory-evoked potentials and other noise-related artefacts. The cause of proposed blink and auditory-evoked potentials was assessed by concatenating known artefacts (i.e. voluntary blinks or auditory-evoked potentials resulting from sham TMS) to the TMS trials before ICA and evaluating grouping of resultant independent components (ICs). Finally, we assessed the effect of removing specific artefact types on TMS-evoked potentials (TEPs) and TMS-evoked oscillations. Results: Over DLPFC, ICs from proposed muscle and decay artefacts correlated with TMS-evoked muscle activity size, whereas proposed TMS-evoked blink ICs combined with voluntary blinks and auditory ICs with auditory-evoked potentials from sham TMS. Individual artefact sub-types characteristically distorted each measure of DLPFC function across the scalp. When free of artefact, TEPs and TMS-evoked oscillations could be measured following DLPFC stimulation. Importantly, characteristic TEPs following motor cortex stimulation (N15, P30, N45, P60, N100) could be recovered from artefactual data, corroborating the reliability of ICA-based artefact correction. Conclusions: Various different artefacts contaminate TMS-EEG recordings over the DLPFC and motor cortex. However, these artefacts can be removed with apparent minimal impact on neural activity using ICA, allowing the study of TMS-evoked cortical network properties. (C) 2014 Elsevier Inc. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据