4.7 Article

An unbiased longitudinal analysis framework for tracking white matter changes using diffusion tensor imaging with application to Alzheimer's disease

期刊

NEUROIMAGE
卷 72, 期 -, 页码 153-163

出版社

ACADEMIC PRESS INC ELSEVIER SCIENCE
DOI: 10.1016/j.neuroimage.2013.01.044

关键词

Unbiased longitudinal image processing; Diffusion tensor imaging; Neurodegenerative diseases; Reliability and precision; Within-subject template

资金

  1. Department of Health's NIHR Biomedical Research Centre
  2. Alzheimer's Research UK
  3. MRC [G0900421, G116/143]
  4. EPSRC [EP/H046410/1]
  5. Computational Biology Research Centre (CBRC) [168]
  6. EPSRC [EP/H046410/1] Funding Source: UKRI
  7. MRC [G0801306, G0601846, G116/143, G0900421] Funding Source: UKRI
  8. Alzheimers Research UK [ARUK-Network2011-6-ICE, ART-EG2010B-1] Funding Source: researchfish
  9. Engineering and Physical Sciences Research Council [EP/H046410/1] Funding Source: researchfish
  10. Medical Research Council [G0900421, G0801306, G0601846, G116/143] Funding Source: researchfish
  11. National Institute for Health Research [NF-SI-0508-10123] Funding Source: researchfish

向作者/读者索取更多资源

We introduce a novel image-processing framework for tracking longitudinal changes in white matter microstructure using diffusion tensor imaging (DTI). Charting the trajectory of such temporal changes offers new insight into disease progression but to do so accurately faces a number of challenges. Recent developments have highlighted the importance of processing each subject's data at multiple time points in an unbiased way. In this paper, we aim to highlight a different challenge critical to the processing of longitudinal DTI data, namely the approach to image alignment Standard approaches in the literature align DTI data by registering the corresponding scalar-valued fractional anisotropy (FA) maps. We propose instead a DTI registration algorithm that leverages full tensor information to drive improved alignment. This proposed pipeline is evaluated against the standard FA-based approach using a DTI dataset from an ongoing study of Alzheimer's disease (AD). The dataset consists of subjects scanned at two time points and at each time point the DTI acquisition consists of two back-to-back repeats in the same scanning session. The repeated scans allow us to evaluate the specificity of each pipeline, using a test-retest design, and assess precision, using bootstrap-based method. The results show that the tensor-based pipeline achieves both higher specificity and precision than the standard FA-based approach. Tensor-based registration for longitudinal processing of DTI data in clinical studies may be of particular value in studies assessing disease progression. (C) 2013 Elsevier Inc. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据