4.7 Article

A comprehensive testing protocol for MRI neuroanatomical segmentation techniques: Evaluation of a novel lateral ventricle segmentation method

期刊

NEUROIMAGE
卷 58, 期 4, 页码 1051-1059

出版社

ACADEMIC PRESS INC ELSEVIER SCIENCE
DOI: 10.1016/j.neuroimage.2011.06.080

关键词

Segmentation; MRI reliability; Sensitivity; Lateral ventricles

资金

  1. National Institute for Health Research (NIHR) Specialist Biomedical Research Centre for Mental Health
  2. Institute of Psychiatry, King's College London
  3. King's College London Centre of Excellence in Medical Engineering
  4. Wellcome Trust
  5. EPSRC [WT 088641/Z/09/Z]
  6. Deutsche Forschungsgemeinschaft [ET 31/2-1]
  7. [P50 AG05681]
  8. [P01 AG03991]
  9. [R01 AG021910]
  10. [P20 MH071616]
  11. [U24 RR021382]

向作者/读者索取更多资源

Although a wide range of approaches have been developed to automatically assess the volume of brain regions from MRI, the reproducibility of these algorithms across different scanners and pulse sequences, their accuracy in different clinical populations and sensitivity to real changes in brain volume have not always been comprehensively examined. Firstly we present a comprehensive testing protocol which comprises 312 freely available MR images to assess the accuracy, reproducibility and sensitivity of automated brain segmentation techniques. Accuracy is assessed in infants, young adults and patients with Alzheimer's disease in comparison to gold standard measures by expert observers using a manual technique based on Cavalieri's principle. The protocol determines the reliability of segmentation between scanning sessions, different MRI pulse sequences and 1.5 T and 3 T field strengths and examines their sensitivity to small changes in volume using a large longitudinal dataset. Secondly we apply this testing protocol to a novel algorithm for segmenting the lateral ventricles and compare its performance to the widely used FSL FIRST and FreeSurfer methods. The testing protocol produced quantitative measures of accuracy, reliability and sensitivity of lateral ventricle volume estimates for each segmentation method. The novel algorithm showed high accuracy in all populations (intraclass correlation coefficient. ICC>0.95), good reproducibility between MRI pulse sequences (ICC>0.99) and was sensitive to age related changes in longitudinal data. FreeSurfer demonstrated high accuracy (ICC>0.95), good reproducibility (ICC>0.99) and sensitivity whilst FSL FIRST showed good accuracy in young adults and infants (ICC>0.90) and good reproducibility (ICC = 0.98), but was unable to segment ventricular volume in patients with Alzheimer's disease or healthy subjects with large ventricles. Using the same computer system, the novel algorithm and FSL FIRST processed a single MRI image in less than 10 min while FreeSurfer took approximately 7 h. The testing protocol presented enables the accuracy, reproducibility and sensitivity of different algorithms to be compared. We also demonstrate that the novel segmentation algorithm and FreeSurfer are both effective in determining lateral ventricular volume and are well suited for multicentre and longitudinal MRI studies. (C) 2011 Elsevier Inc. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据