4.8 Article

Detecting single viruses and nanoparticles using whispering gallery microlasers

期刊

NATURE NANOTECHNOLOGY
卷 6, 期 7, 页码 428-432

出版社

NATURE PUBLISHING GROUP
DOI: 10.1038/NNANO.2011.99

关键词

-

资金

  1. National Science Foundation [0907467, 0954941]
  2. NRF/NNIN (NSF) of Washington University in St. Louis [ECS-0335765]
  3. Division Of Materials Research
  4. Direct For Mathematical & Physical Scien [0907467] Funding Source: National Science Foundation

向作者/读者索取更多资源

There is a strong demand for portable systems that can detect and characterize individual pathogens and other nanoscale objects without the use of labels, for applications in human health, homeland security, environmental monitoring and diagnostics(1-6). However, most nanoscale objects of interest have low polarizabilities due to their small size and low refractive index contrast with the surrounding medium. This leads to weak light-matter interactions, and thus makes the label-free detection of single nanoparticles very difficult. Micro-and nanophotonic devices have emerged as highly sensitive platforms for such applications, because the combination of high quality factor Q and small mode volume V leads to significantly enhanced light-matter interactions(7-15). For example, whispering gallery mode microresonators have been used to detect and characterize single influenza virions(10) and polystyrene nanoparticles with a radius of 30 nm (ref. 12) by measuring in the transmission spectrum either the resonance shift(10) or mode splitting(12) induced by the nanoscale objects. Increasing Q leads to a narrower resonance linewidth, which makes it possible to resolve smaller changes in the transmission spectrum, and thus leads to improved performance. Here, we report a whispering gallery mode microlaser-based real-time and label-free detection method that can detect individual 15-nm-radius polystyrene nanoparticles, 10-nm gold nanoparticles and influenza A virions in air, and 30 nm polystyrene nanoparticles in water. Our approach relies on measuring changes in the beat note that is produced when an ultra-narrow emission line from a whispering gallery mode microlaser is split into two modes by a nanoscale object, and these two modes then interfere. The ultimate detection limit is set by the laser linewidth, which can be made much narrower than the resonance linewidth of any passive resonator(16,17). This means that microlaser sensors have the potential to detect objects that are too small to be detected by passive resonator sensors(18).

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据