4.8 Article

Graphene and Nanowire Transistors for Cellular Interfaces and Electrical Recording

期刊

NANO LETTERS
卷 10, 期 3, 页码 1098-1102

出版社

AMER CHEMICAL SOC
DOI: 10.1021/nl1002608

关键词

Nanoelectronic device; nano-bioelectronics; field-effect transistor; electrophysiology; cardiomyocytes

资金

  1. Special Presidential Foundation of the Chinese Academy of Sciences, China [08172911ZX]
  2. National Natural Science Foundation of China [20973045]
  3. NIH [1DP1OD003900]
  4. National Security Science and Engineering Faculty Fellow (NSSEFF) [N00244-09-1-0078]
  5. OFFICE OF THE DIRECTOR, NATIONAL INSTITUTES OF HEALTH [DP1OD003900] Funding Source: NIH RePORTER

向作者/读者索取更多资源

Nanowire held-effect transistors (NW-FETs) have been shown to be powerful building blocks for nanoscale bioelectronic interfaces with cells and tissue due to their excellent sensitivity and their capability to form strongly coupled interfaces with cell membranes. Graphene has also been shown to be an attractive building block for nanoscale electronic devices, although little is known about its interfaces with cells and tissue. Here we report the first studies of graphene held effect transistors (Gra-FETs) as well as combined Gra- and NW-FETs interfaced to electrogenic cells. Gra-FET conductance signals recorded from spontaneously beating embryonic chicken cardiomyocytes yield well-defined extracellular signals with signal-to-noise ratio routinely > 4. The conductance signal amplitude was tuned by varying the Gra-FET working region through changes in water gate potential, V-wg. Signals recorded from cardiomyocytes for different V-wg result in constant calibrated extracellular voltage, indicating a robust graphene/cell interface. Significantly, variations in V-wg across the Dirac point demonstrate the expected signal polarity flip. thus allowing, for the first time, both n- and p-type recording to be achieved from the same Gra-FET simply by offsetting V-wg. In addition, comparisons of peak-to-peak recorded signal widths made as a function of Gra-FET device sizes and versus NW-FETs allowed an assessment of relative resolution in extracellular recording. Specifically, peak-to-peak widths increased with the area of Gra-FET devices, indicating an averaged signal from different points across the outer membrane of the beating cells. One-dimensional silicon NW-FETs incorporated side by side with the two-dimensional Gra-FET devices further highlighted limits in both temporal resolution and multiplexed measurements from the same cell For the different types of devices. The distinct and complementary capabilities of Gra- and NW-FETs could open up unique opportunities in the held of bioelectronics in the future.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据