4.7 Article

Electrogenerated chemiluminescence biosensors for the detection of pathogenic bacteria using antimicrobial peptides as capture/signal probes

期刊

SENSORS AND ACTUATORS B-CHEMICAL
卷 210, 期 -, 页码 468-474

出版社

ELSEVIER SCIENCE SA
DOI: 10.1016/j.snb.2015.01.011

关键词

Biosensor; Bacteria; Escherichia coli; Electrogenerated chemiluminescence; Antimicrobial peptide

资金

  1. National Science Foundation of China [21475082, 21328501, 21375084, 21275095]
  2. Natural Science Basic Research Plan in Shaanxi Province of China [2013KJXX-73]
  3. Science and Technology Innovation Coordination Project of Shaanxi Province [2013SZS08-P01]
  4. Open Funds of the State Key Laboratory of Electroanalytical Chemistry [SKLEAC201404]

向作者/读者索取更多资源

Two electrogenerated chemiluminescence (ECL) biosensors for selective and sensitive detection of Escherichia coli O157:H7 were first designed by employing the antimicrobial peptide Magainin I as a biological recognition element and the ruthenium complex (Ru1) as an ECL label. In a direct format, the biosensor (I) was fabricated by self-assembling the Ru1-labeled peptide taken as a capture and signal probe onto the gold electrode surface. This system showed that the decreased ECL intensity was logarithmically proportional to the concentration of E. coli O157:H7 in the range of 1.0 x 10(3) - 5.0 x 10(5) CFU/mL, with a detection limit of 2.3 x 10(2) CFU/mL. In a sandwich format, the biosensor (II) was fabricated by self-assembling the modified Magainin I taken as capture probe onto the gold electrode surface. After E. coli O157:H7 was captured by the capture probe on the biosensor (II) and then bound with the Ru1-labeled peptide as the signal probe, the increased ECL intensity was logarithmically proportional to the concentration of E. coli from 5.0 x 10(2) CFU/mL to 5.0 x 10(5) CFU/mL, with a detection limit of 1.2 x 10(2) CFU/mL. Importantly, the designed ECL biosensors showed a satisfactory selectivity in discriminating the gram-negative E. coli O157:H7 from gram-positive bacteria, and pathogenic from nonpathogenic E. coli. The strategy of using a Ru1-labeled peptide as a capture/signal probe is a promising approach to designing ECL biosensors for highly sensitive and rapid detection of E. coli O157:H7; this approach could be extended to the design of ECL biosensors for other desired bacteria as well. (C) 2015 Published by Elsevier B.V.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据