4.6 Article

Advances in source technology for focused ion beam instruments

期刊

MRS BULLETIN
卷 39, 期 4, 页码 329-335

出版社

CAMBRIDGE UNIV PRESS
DOI: 10.1557/mrs.2014.53

关键词

Scanning probe microscopy; secondary ion mass spectrometry; ion beam analysis; ion beam assisted deposition

向作者/读者索取更多资源

Owing to the development of new ion source technology, users of focused ion beams (FIBs) have access to superior performance when compared with the industry standard Ga+ liquid metal ion source. FIBs equipped with an inductively coupled plasma (ICP) ion source are better able to carry out large volume milling applications by providing up to 2 mu A of Xe+ ions focused into a sub-5 mu m spot. However, ICP FIBs are presently limited to 25 nm imaging resolution at 1 pA.The gas field ionization source (GFIS) relies upon an ion source that is the size of a single atom and correspondingly gains high brightness through its very small source size. The high brightness allows the GFIS to produce a very small focused probe size (<0.35 nm for helium), but with comparatively small beam currents (less than 2 pA). The Cs+ low temperature ion source, still being developed, has a projected sub-nm focal spot size at 1 pA, a maximum current of several nanoamps, and has the potential to offer integrated secondary ion mass spectrometry capabilities.