4.7 Article

Maximizing collection and minimizing risk: does vacuum suction sampling increase the likelihood for misinterpretation of food web connections?

期刊

MOLECULAR ECOLOGY RESOURCES
卷 10, 期 6, 页码 1023-1033

出版社

WILEY
DOI: 10.1111/j.1755-0998.2010.02857.x

关键词

food web connections; general aphidoid primers; generalist predators; molecular gut-content analysis; Tetragnathidae; vacuum suction sampling

资金

  1. Kentucky Science and Engineering Foundation [KSEF-148-502-08-225]
  2. University of Kentucky Agricultural Experiment Station [KY008043]
  3. Office of the Vice President for Research
  4. Kentucky Science and Technology Corporation

向作者/读者索取更多资源

Molecular tools that characterize the structure of complex food webs and identify trophic connectedness in the field have become widely adopted in recent years. However, characterizing the intensity of predator-prey interactions can be prone to error. Maximizing collection success of small, fast-moving predators with vacuum suction samplers has the potential to increase the likelihood of prey DNA detection either through surface-level contamination with damaged prey or direct consumption within the sampling device. In this study, we used PCR to test the hypothesis that vacuum suction sampling will not cause an erroneous increase in the detection of 'predation', thereby incorrectly assigning trophic linkages when evaluating food web structure. We utilized general (1) Aphidoidea and (2) Collembola primers to measure the predation rates of Glenognatha foxi (Araneae: Tetragnathidae) on these prey collected by hand versus those sampled with a vacuum suction device. With both primer pairs, there was no significant increase in predators screening positive for prey DNA when sampled by vacuum suction versus those predators collected, in parallel, by hand. These results clearly validate the application of vacuum suction sampling during molecular gut-content analysis of predator-prey feeding linkages in the field. Furthermore, we found no evidence that predation was occurring inside the suction sampler because specimens collected were never observed to be feeding nor did they screen positive at greater frequencies than hand-collected individuals. Therefore, it can be concluded that the use of vacuum suction sampling devices (in this case a Modified CDC Backpack Aspirator Model 1412) is suitable for molecular gut-content analysis.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据