Objective The primary objective of this study was to evaluate 1-week reproducibility of post-occlusive reactive hyperemia (PORH) and local thermal hyperemia (LTH) assessed by single-point laser-Doppler flowmetry (LDF) on different skin sites. We also evaluated spatial reproducibility of both tests on the forearm Finally, we assessed the influence of mental stress and room temperature variations on PORH and LTH Methods We performed PORH and LTH assessing skin blood flow on the forearm and oil the finger pad with LDF. We repeated the sequence 1 week later We also performed PORH and LTH during mental stress (Stroop test) and at room temperatures of 21 degrees C and 27 degrees C Data were expressed as cutaneous vascular conductance (CVC), as a function of baseline and as a function of 44 degrees C vasodilation (%CVC(44)) Reproducibility was expressed as within subject coefficients of variation (CV) and intra-class correlation coefficients (ICC) Results Fourteen Caucasian healthy volunteers were recruited Median age was 25 (2 7) and 50% were female Median body mass index was 21 2 (5) PORH was reproducible oil the finger, whether expressed as raw CVC (CV = 25%, ICC = 0 56) or as %CVC(44) (CV = 24%, ICC = 0.60). However, PORH showed poor reproducibility on the forearm In the same way, LTH was reproducible on the finger pad when expressed as CVC (CV = 17%, ICC = 0 81) but not on the forearm Spatial reproducibility was poor on the forearm. Elevated room temperature (27 degrees C) affected PORH and LTH oil the finger pad (p<005) but not oil the forearm Conclusion. Single-point LDF is a reproducible technique to assess PORH and LTH on the finger pad when data are expressed as raw CVC or %CVC(44) On the forearm, however. it shows great inter-day variability, probably due to spatial variability of capillary density These results highlight the need for alternative techniques on the forearm (C) 2010 Elsevier Inc All rights reserved

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据