Spin coating of hydrophilic polymeric films for enhanced centrifugal flow control by serial siphoning

期刊

MICROFLUIDICS AND NANOFLUIDICS
卷 16, 期 4, 页码 691-699

出版社

SPRINGER HEIDELBERG
DOI: 10.1007/s10404-013-1266-x

关键词

Hydrophilic polymers; Spin coating; Centrifugal microfluidic platform; Lab-on-a-disc; Serial siphoning; Capillary valving

资金

  1. FP7 ENIAC programme CAJAL4EU
  2. ERDF
  3. Enterprise Ireland [IR/2010/0002]
  4. Science Foundation of Ireland [10/CE/B1821]

向作者/读者索取更多资源

In this paper, we implement rotational flow control on a polymeric microfluidic lab-on-a-disc platform by combining serial siphoning and capillary valving for sequential release of a set of on-board stored liquid reagents into a common (assay) channel. The functionality of this integrated, multi-step, multi-reagent centrifugal assay platform critically depends on the capability to establish very reproducible, capillary-driven priming of the innately only weakly hydrophilic siphon microchannels made from common poly(methyl methacrylate) (PMMA) substrates. Due to the relatively high contact angle of the native PMMA substrate, it was practically impossible to ensure sequential release of on-board stored reagents using the capillary-driven serial siphon valves. In this work, we demonstrate that spin-coated hydrophilic films of poly(vinyl alcohol) (PVA) and (hydroxypropyl)methyl cellulose (HPMC) provide stable contact angles on PMMA substrates for more than 60 days. The deposited films were characterized using contact angle measurements, surface energy calculations and X-ray photoelectron spectroscopy spectra. The PVA and HPMC films reduced the water contact angle of the PMMA substrate from 68A degrees to 22A degrees and 27A degrees while increasing their surface energies from 47 to 62 and 57 mN m(-1), respectively. On the centrifugal microfluidic platform, the films were validated to enable the effective and reproducible priming of the serial siphon microchannels at low rotational frequencies while ensuring that the in-line capillary valves are not opened until their respective burst frequencies are passed. Furthermore, the biocompatibility of the proposed surface modification method was examined, and the platform was used to run a sandwich immunoassay for the detection of human immunoglobulin G, and its performance was proven to be comparable to dynamic coating using surfactants.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据