4.7 Article

Performance analysis of a heat pipe PV/T system with different circulation tank capacities

期刊

APPLIED THERMAL ENGINEERING
卷 87, 期 -, 页码 89-97

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.applthermaleng.2015.04.074

关键词

Heat pipe PV/T system; Tank capacity; Efficiency; TRNSYS

资金

  1. Commission of Science and Technology of Tianjin [13ZCZDNC01400]
  2. University Development Fund Projects of Science and Technology in Tianjin [20140424]
  3. State Key Laboratory Project about Building Safety and Environment [BSBE2014-07]

向作者/读者索取更多资源

The tank volume and tilt angle of a photovoltaic/thermal (PV/T) are key parameters for a heat pipe PV/T system, and the two parameters are optimized in this paper. Hot water and electric power generation are also calculated. A simulation model of the heat pipe PV/T system was established using the TRNSYS, and the numerical results were validated by experimental data. The results show that hot water and electric power generation initially decrease and then increase with the volume of the circulating tank. The highest integrated efficiency reaches 67.5% while the volume of the circulating tank is 80 L The orientation and tilt angle of the heat pipe PV/T collector were optimized based on the simulation model. The mean annual efficiency of the PV/T system is about 4.37%, and the heat collection is about 2328.16 MJ/year. (C) 2015 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据