Ultra performance liquid chromatography (UPLC) hyphenated to tandem mass spectrometry (MS/MS) was used for the development of an analytical method capable of simultaneous identification and quantification of 18 beta-agonist compounds namely, brombuterol, chlorbrombuterol, cimaterol, cimbuterol, clenbuterol, clencyclohexerol, clenisopenterol, clenpenterol, clenproperol, hydroxymetylclenbuterol, isoxsuprine, mabuterol, mapenterol (clenbuterol-like compounds), ractopamine, ritodrine, salbutamol, salmeterol (salbutamol-like compounds) and zilpaterol in bovine urine. In compliance with the Commission Decision 2002/657/EC (CD 2002/657/EC), the method was validated applying a matrix-comprehensive in-house validation approach based on a fractional factorial design. Six experimental factors varied on two levels were selected for this purpose. The relevant validation parameters such as decision limit CC alpha (range, 0.24-0.51 mu g L-1) and detection capability cc beta (range, 0.27-0.71 mu g L-1), within-laboratory reproducibility (<20%) as well as recovery (range, 92-109%) were in agreement with the performance criteria set in the CD 2002/657/EC. Overall, the proposed method enabled both screening and confirmatory detection of the beta-agonist compounds in the framework of official monitoring plans. (C) 2014 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据