4.7 Article

On-line solid phase extraction of Cd from protein fractions of serum using oxidized carbon nanotubes coupled to electrothermal atomization atomic absorption spectrometry

期刊

MICROCHEMICAL JOURNAL
卷 110, 期 -, 页码 94-98

出版社

ELSEVIER
DOI: 10.1016/j.microc.2013.03.003

关键词

Cadmium; Serum protein fractions; Cellulose acetate electrophoresis; Oxidized carbon nanotubes; ETAAS

资金

  1. Instituto de Quimica de San Luis from the Universidad Nacional de San Luis and Consejo Nacional de Investigaciones Cientificas y Tecnicas (UNSL-CONICET)
  2. Agencia Nacional de Promocion Cientifica (FONCYT)

向作者/读者索取更多资源

This work presents a sensitive and accurate method for Cd determination in serum protein fractions separated by cellulose acetate electrophoresis (CAE). The determinations were carried out by on-line solid phase extraction using oxidized carbon nanotubes coupled to electrothermal atomization atomic absorption spectrometry (ETAAS). The detection and quantification limits were 10 ng L-1 and 35 ng L-1 respectively with a precision of 4.0% as relative standard deviation. This procedure joined the simplicity of protein separation by CAE, the preconcentration properties of solid phase extraction using ox-CNT and the excellent sensitivity attainable by ETAAS. The method was applied to samples with biological relevance (humans and experimental rats). Our work demonstrated that Cd could be determined in serum protein fractions separated by electrophoresis with good accuracy using the proposed method. (C) 2013 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据