4.7 Article

Development of a solid phase extraction method for the multielement determination of trace metals in natural waters including sea-water by FI-ICP-MS

期刊

MICROCHEMICAL JOURNAL
卷 101, 期 -, 页码 87-94

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.microc.2011.11.003

关键词

Inductively coupled plasma mass spectrometry; Sea-water; On-line preconcentration; Metals

资金

  1. Junta de Andalucia [P07-RNM-02502]
  2. Spanish Ministerio de Ciencia y Tecnologia (MCyT) [CTQ 2009-07858]
  3. FEDER

向作者/读者索取更多资源

An automated solid phase extraction method by flow analysis on-line inductively coupled plasma mass spectrometry (FI-ICP-MS) for the determination of cobalt, chromium, nickel, cadmium, manganese, zinc, copper and lead in sea-water and other natural waters is described. The system is based on retention of the analytes onto a minicolumn packed with a chelating resin, 1,5-bis (2-pyridyl)-3-sulphophenyl methylene thiocarbonohydrazide immobilized on aminopropyl-controlled pore glass, placed in the injection valve of a simple flow manifold. The effects of chemical and flow variables were investigated and selected as a compromise between sensitivity and sampling frequency. So, the sample solutions (adjusted to pH 8.0 +/- 0.5) were passed through the column. After washing the column with water, the adsorbed metals were subsequently eluted into the plasma with 4% m/m nitric acid. Detection limits of the trace metals (180 s sample loading time at a sample flow rate of 0.7 mL min(-1); sampling frequency 8.6 h(-1)) were 0.002 mu g L-1 for Co, 0.057 mu g L-1 for Cr, 0.117 mu g L-1 for Ni, 0.004 mu g L-1 for Cd, 0.210 mu g L-1 for Mn, 0.260 mu g L-1 for Zn, 0.030 mu g L-1 for Cu and 0.020 mu g L-1 for Pb, with enrichment factors between 2.2 and 6.8. The accuracy of the proposed method was checked with certified reference materials (CRMs) of sea-water SLEW 3, LGC6016 and CASS-5, river water SLRS-5 and fortified lake water TMDA-54.4. The results from the determination of these metals were in agreement with the certified values and recovery values ranged between 92.2 and 110.6%. The method was applied to the determination of these metal ions in sea-water samples collected in the Malaga Bay in order to realize a pilot study necessary to generate preliminary information on which to base a more detailed pollution study by heavy metals of the Bay. (C) 2011 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据