4.7 Article

Method development for simultaneous multi-element determination of hydride forming elements (As, Bi, Ge, Sb, Se, Sn) and Hg by microwave induced plasma-optical emission spectrometry using integrated continuous-microflow ultrasonic nebulizer-hydride generator sample introduction system

期刊

MICROCHEMICAL JOURNAL
卷 95, 期 2, 页码 213-221

出版社

ELSEVIER SCIENCE BV
DOI: 10.1016/j.microc.2009.12.004

关键词

Dual-mode sample introduction system; Ultrasonic nebulizer (USN); Analytical samples; Chemical vapor generation (CVG); Trace elements; Microwave induced plasma-optical emission spectrometry (MIP-OES)

资金

  1. Committee for Scientific Research, Poland [COST/48/2006]

向作者/读者索取更多资源

The analytical potential of a coupled continuous-microflow ultrasonic nebulizer dual capillary system (mu-USN/DCS)-Ar/He mixed gas microwave induced plasma-optical emission spectrometry (MIP-OES) has been evaluated for the purpose of determination of hydride forming elements (As, Bi, Ge, Sb, Se, Sn) and a vapor element (Hg) A univariate approach and the simplex optimization procedure were used to achieve optimized conditions and derive analytical figures of merit. Analytical performance of the ultrasonic nebulization system was characterized by determination of the limits of detection (LODs) and precision (RSDs) with the mu-USN/DCS observed at a 15 mu L min(-1) flow rate At flows of <= 15 mu L min(-1). solvent loading in the plasma is sufficiently low to make desolvation unnecessary. The experimental concentration detection limits for simultaneous determination, calculated as the concentration giving a signal equal to three times of the standard deviation of the blank (LOD, 3 sigma(blank) criterion, peak height) were 1 2, 54, 6.3, 1 8, 3.3, 24 and 30 ng mL(-1) for As, Bi, Cc, Sb, Se, Sn and Hg. respectively The method offers relatively good precision (RSD ranged from 8 to 11%) for liquid analysis and microsampling capability. Interference effects by transition metals have been shown to be corrected by the addition of thiourea, as a pre-reducing agent and masking agent The accuracy of the method was verified using certified reference materials (DOLT-2, GBW 07302, SRM 2710, and SRM 1643e) and by the aqueous standard calibration technique. The measured contents of elements in reference materials were in satisfactory agreement with the certified values (C) 2009 Elsevier B V All rights reserved

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据