4.6 Article

Stress corrosion cracking of alloy 600 in an aqueous solution containing lead oxide

期刊

METALS AND MATERIALS INTERNATIONAL
卷 16, 期 2, 页码 259-266

出版社

KOREAN INST METALS MATERIALS
DOI: 10.1007/s12540-010-0415-y

关键词

metals; oxides; corrosion; SEM(scanning electron microscopy); AES(Auger electron spectroscopy)

资金

  1. Ministry of Education, Science and Technology (MEST) of Korea

向作者/读者索取更多资源

The stress corrosion cracking (SCC) behavior of Alloy 600 was studied in aqueous solutions containing lead. Electrochemical polarization and current transient experiments were performed at 315 A degrees C in a 40% sodium hydroxide solution to assess the effect of lead on a passive film formed on Alloy 600. The influences of the alloy microstructure and the addition of an inhibitor to the environments on lead-induced SCC were investigated using C-ring and slow strain-rate tensile (SSRT) tests in demineralized high-purity water and caustic solutions containing PbO at 315 A degrees C. The surface films on Alloy 600 were examined using Auger electron spectroscopy (AES) and energy dispersive x-ray spectroscopy (EDXS). The PbO markedly accelerated SCC of Alloy 600 in the caustic solution and the high-purity water at 315 A degrees C. The addition of nickel boride (NiB) or cerium boride (CeB(6)) to the test solutions decreased the susceptibility of Alloy 600 to SCC. Thermally treated Alloy 600 (Alloy 600 TT) tended to crack in a transgranular mode, while the solution-annealed Alloy 600 (Alloy 600 SA) tended to crack in an intergranular mode in water containing PbO.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据