Analytical, numerical and experimental analyses have been performed to investigate the effects of thermocouple wire electrical insulation on the temperature measurement of a reference surface. Two diameters of type K thermocouple, 80 mu m and 200 mu m, with different exposed wire lengths (0 mm, 5 mm, 10 mm, 15 mm and 20 mm) were used to measure various surface temperatures (4 degrees C, 8 degrees C, 15 degrees C, 25 degrees C and 35 degrees C). Measurements were made with the thermocouple in direct contact with the surface, with wires extending vertically and exposed to natural convection. Analytical results of the thermocouple wire with insulation confirm that there is no specific value for the critical radius and the rate of heat flux around the thermocouple wire continuously increases with the wire diameter even when this is larger than the critical radius. Numerical simulation using COMSOL Multiphysics software also confirms that there is negligible thermal effect from the electrical insulation. Moreover, the experimental results agree well with those obtained by both the analytical and numerical methods and further confirm that the diameter of the thermocouple has an impact on the temperature measurement. (C) 2015 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据