期刊
MEAT SCIENCE
卷 82, 期 4, 页码 407-412出版社
ELSEVIER SCI LTD
DOI: 10.1016/j.meatsci.2008.09.011
关键词
Matrix solid-phase dispersion; Pyrethroid; Porcine tissue; High-performance liquid chromatography
An effective matrix solid-phase dispersion (MSPD) extraction for determination of two pyrethroids (cypermethrin and deltamethrin) in porcine tissues (liver, muscle, heart and kidney) is described. A neutral alumina-based MPSD column was used for extraction of analytes. The high-performance liquid chromatography and ultraviolet detector was applied using a reverse-phase C-18 column and acetonitrile-water (85:15, v/v) was used as mobile phase. The good linear fit curve ranging from 0.05 to 50 mu g mL(-1) for cypermethrin (CM) and deltamethrin (DM) was obtained with a regression coefficient (r) of 0.999. Recoveries at 0.2 and 0.5 mu g g(-1) levels were between 83.5% and 109%. The limits of detection and quantification were: 0.01 and 0.026 mu g g(-1) for CM, 0.017 and 0.056 mu g g(-1) for DM, respectively. The proposed method was successfully applied to the determination of the pyrethroids in porcine tissues. (C) 2008 Published by Elsevier Ltd.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐