Measurement of liquid film thickness by optical fluorescence and its application to an oscillating piston positive displacement flowmeter

期刊

MEASUREMENT SCIENCE AND TECHNOLOGY
卷 22, 期 12, 页码 -

出版社

IOP PUBLISHING LTD
DOI: 10.1088/0957-0233/22/12/125403

关键词

flowmeter; film thickness; fluorescence; high speed photography

资金

  1. UK Engineering and Physical Sciences Research Council (EPSRC)
  2. Litre Meter Ltd.
  3. Gatsby Charitable Foundation

向作者/读者索取更多资源

The movement of the circular piston in an oscillating piston positive displacement flowmeter is important in understanding the operation of the flowmeter, and the leakage of liquid past the piston plays a key role in the performance of the meter. The clearances between the piston and the chamber are small, typically less than 60 mu m. In order to measure this film thickness a fluorescent dye was added to the water passing through the meter, which was illuminated with UV light. Visible light images were captured with a digital camera and analysed to give a measure of the film thickness with an uncertainty of less than 7%. It is known that this method lacks precision unless careful calibration is undertaken. Methods to achieve this are discussed in the paper. The grey level values for a range of film thicknesses were calibrated in situ with six dye concentrations to select the most appropriate one for the range of liquid film thickness. Data obtained for the oscillating piston flowmeter demonstrate the value of the fluorescence technique. The method is useful, inexpensive and straightforward and can be extended to other applications where measurement of liquid film thickness is required.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据