4.3 Article

CFD Analysis of Heat Transfer and Friction Factor Characteristics in a Circular Tube Fitted with Quadrant-Cut Twisted Tape Inserts

期刊

MATHEMATICAL PROBLEMS IN ENGINEERING
卷 2013, 期 -, 页码 -

出版社

HINDAWI LTD
DOI: 10.1155/2013/273764

关键词

-

资金

  1. Universiti Kebangsaan Malaysia
  2. Ministry of Higher Education [FRGS/1/2013/TK07/UKM/01/1]

向作者/读者索取更多资源

This paper reports numerical investigations of heat transfer and friction factor characteristics in swirling flow conditions using CFD simulation. A commercial CFD package, FLUENT 6.3.26, was used in this study. 3D models for circular tube fitted with classical and quadrant-cut twisted tape (QCT) inserts with three twist ratios (y = 2.93, 3.91, and 4.89) and different cut depths (w = 0.5, 1.0, and 1.5 cm) were generated for the simulation. The data obtained from the CFD simulation were verified with the literature correlations of plain tube with the discrepancy of less than +/- 8% for Nusselt number and +/- 10% for friction factor. The results show that there was a significant increase in heat transfer coefficient and friction factor in the tube fitted with quadrant-cut twisted tape (QCT) with decreasing of twist ratio (y) and cut depth (w). Furthermore, the configuration of QCT insert with a twist ratio of y = 2.93 and a cut depth of w = 0.5 cm offered higher heat transfer rate and friction factor than other twist ratios.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据