4.7 Article

Effect of laser shock peening on residual stress and fatigue life of clad 2024 aluminium sheet containing scribe defects

出版社

ELSEVIER SCIENCE SA
DOI: 10.1016/j.msea.2012.04.002

关键词

Laser peening; Aluminium sheet; Fatigue; Residual stresses; Crack growth

资金

  1. Open University from The Lloyd's Register Educational Trust

向作者/读者索取更多资源

Laser peening at a range of power densities has been applied to 2 mm-thick sheets of 2024 T351 aluminium. The induced residual stress field was measured using incremental hole drilling and synchrotron X-ray diffraction techniques. Fatigue samples were subjected to identical laser peening treatments followed by scribing at the peen location to introduce stress concentrations, after which they were fatigue tested. The residual stresses were found to be non-biaxial: orthogonal to the peen line they were tensile at the surface, moving into the desired compression with increased depth. Regions of peen spot overlap were associated with large compression strains; the centre of the peen spot remaining tensile. Fatigue lives showed moderate improvement over the life of unpeened samples for 50 mu m deep scribes, and slight improvement for samples with 150 mu m scribes. Use of the residual stress intensity K-resid approach to calculate fatigue life improvement arising from peening was unsuccessful at predicting the relative effects of the different peening treatments. Possible reasons for this are explored. (C) 2012 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据