Radioaerosol Pulmonary Deposition Using Mesh and Jet Nebulizers During Noninvasive Ventilation in Healthy Subjects

期刊

RESPIRATORY CARE
卷 60, 期 9, 页码 1238-1246

出版社

DAEDALUS ENTERPRISES INC
DOI: 10.4187/respcare.03667

关键词

nebulizer; noninvasive ventilation; inhalation device; aerosol; pulmonary scintigraphy; radioaerosol

资金

  1. Fundacao de Amparo a Ciencia e a Pesquisa (FACEPE)
  2. Conselho Nacional de Desenvolvimento Cientifico e Tecnologico (CNPq)

向作者/读者索取更多资源

BACKGROUND: In vivo deposition studies of aerosol administration during noninvasive ventilation (NIV) are scarce in the literature. The aim of this study was to compare radioaerosol pulmonary index and radioaerosol mass balance in the different compartments (pulmonary and extrapulmonary) of radio-tagged aerosol administered using vibrating mesh nebulizers and conventional jet nebulizers during NIV. METHODS: This was a crossover clinical trial involving 10 healthy subjects (mean age of 33.7 +/- 10.0 y) randomly assigned to both treatment arms of this study: group 1 (NIV + vibrating mesh nebulizer, n = 10) and group 2 (NIV + jet nebulizer, n = 10). All subjects inhaled 3 mL of technetium-99m diethylenetriaminepentaacetic acid (25 mCi) and 0.9% saline solution via vibrating mesh and jet nebulizers during NIV through a face mask secured with straps while receiving positive inspiratory and expiratory pressures of 12 and 5 cm H2O, respectively. Scintigraphy was performed to count radioaerosol particles deposited in the regions of interest to determine radioaerosol mass balance from the lungs, upper airways, stomach, nebulizer, ventilator circuit, inspiratory and expiratory filters, and mask as a percentage. RESULTS: Vibrating mesh nebulizers deposited 972,013 +/- 214,459 counts versus jet nebulizer with 386,025 +/- 130,363 counts (P =.005). In a determination of mass balance, vibrating mesh nebulizers showed a higher deposition of inhaled radioaerosol compared with jet nebulizers (23.1 +/- 5.8% vs 6.1 +/- 2.5%, P =.005) and a higher proportion of radioaerosol deposited into the lungs (5.5 +/- 0.9% versus 1.5 +/- 0.6%, respectively, P =.005). The residual drug volume was lower with vibrating mesh nebulizers (5.1 +/- 1.5%) compared with jet nebulizers (41.3 +/- 4.2%, P =.005). CONCLUSIONS: During NIV in healthy subjects, vibrating mesh nebulizers delivered > 2-fold more radiolabeled drug into the respiratory tract compared with conventional jet nebulizers. Additional studies are recommended in subjects with asthma, COPD, bronchiectasis, and cystic fibrosis to better understand differences in both aerosol delivery and response. (c) 2015 Daedalus Enterprises

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.2
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据