4.7 Article

A critical comparison of various data processing methods in simple uni-axial compression testing

期刊

MATERIALS & DESIGN
卷 32, 期 5, 页码 2797-2802

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.matdes.2011.01.007

关键词

Ferrous metals and alloys; Forging; Plastic behaviour

向作者/读者索取更多资源

The paper compares the error associated with various data processing methods to obtain true stress-plastic strain data from the load-deformation curves generated from uni-axial compression tests. Towards this end, uni-axial compression tests have been conducted on three representative materials viz modified 9Cr-1Mo ferritic steels, alloy D9 (a titanium modified austenitic stainless steel) and 316L(N) austenitic stainless steel in wide ranges of temperatures and strain rates. It has been observed that the absolute average error associated with maximum true plastic strain calculation in all the three materials is always more than 5% and sometimes as high as 42.1% if the elastic region is removed either from the load-stroke curve or engineering stress-strain curve to get the true stress-plastic strain curve. However, the absolute average error associated with plastic strain calculation is always less than 5% if the elastic region is removed from the true stress-strain curve. (C) 2011 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据