4.7 Article

Progressive fatigue failure behavior of glass/epoxy (±75)2 filament-wound pipes under pure internal pressure

期刊

MATERIALS & DESIGN
卷 30, 期 10, 页码 4293-4298

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.matdes.2009.04.025

关键词

Polymer matrix composites; Filament winding; Fatigue; Fractography; Failure analysis

资金

  1. Selcuk University

向作者/读者索取更多资源

Fatigue failure behaviors of filament-wound composite pipes under pure internal pressure were investigated. The filament-wound pipes are made of E-glass/epoxy and have four layers which have +/-75 degrees winding angle. The fatigue tests have been done in accordance with ASTM D-2992, which stipulate 0.42 Hz frequency and R = 0.05 stress ratio. Tests have been performed at different load levels from 30% to 70% of ultimate tangential strength of the pipe, the damage progression such as whitening, leakage and final failure have been observed, and S-N curves of these damages were obtained. (C) 2009 Elsevier Ltd. All rights reserved.