期刊
MAGNETIC RESONANCE IN MEDICINE
卷 72, 期 5, 页码 1418-1426出版社
WILEY-BLACKWELL
DOI: 10.1002/mrm.25032
关键词
diffusion; prostate; modelling; Akaike Information Criterion
资金
- Australian NHMRC [APP1026467]
- Australian National Imaging Facility
- EPSRC [EP/E007748, EP/H046410/01]
- Engineering and Physical Sciences Research Council [EP/H046410/1, EP/G007748/1] Funding Source: researchfish
- EPSRC [EP/G007748/1, EP/H046410/1] Funding Source: UKRI
PurposeTo compare the theoretical information content of four popular models of diffusion-weighted signal attenuation. MethodFour whole prostates were imaged fresh unfixed and fixed at 9.4T. Biexponential, kurtosis, stretched exponential, and monoexponential models were ranked using Akaike's Information Criterion (AIC) with validation by a leave-one-out test of model prediction error. ResultsFor unfixed tissue measurements (b-value range: 17-2104 s/mm(2)) the biexponential and kurtosis models had similar information content to each other and this was distinctly higher than for the stretched and monoexponential models. In fixed-tissue measurements (b-value range: 17-8252 s/mm(2)), the biexponential model had much higher information content than the three other models. ConclusionAIC-based model ranking is consistent with an independent prediction accuracy test. Biexponential and kurtosis models consistently perform better than stretched and monoexponential models. The biexponential model has increasing superiority over all three other models as maximum b-value increases above approximate to 2000 s/mm(2). Magn Reson Med 72:1418-1426, 2014. (c) 2013 Wiley Periodicals, Inc.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐
暂无数据