4.5 Article

Improved Renal Perfusion Measurement With a Dual Navigator-Gated Q2TIPS FAIR Technique

期刊

MAGNETIC RESONANCE IN MEDICINE
卷 64, 期 5, 页码 1352-1359

出版社

WILEY
DOI: 10.1002/mrm.22532

关键词

arterial spin labeling; navigator gating; perfusion; renal blood flow; True-FISP

资金

  1. NHLBI [2U54HL070590-06]
  2. American Lebanese Syrian Associated Charities

向作者/读者索取更多资源

A dual navigator-gated, flow-sensitive alternating inversion recovery (FAIR) true fast imaging with steady precession (True-FISP) sequence has been developed for accurate quantification of renal perfusion. FAIR methods typically overestimate renal perfusion when respiratory motion causes the inversion slice to move away from the imaging slice, which then incorporates unlabeled spins from static tissue. To overcome this issue, the dual navigator scheme was introduced to track inversion and imaging slices, and thus to ensure the same position for both slices. Accuracy was further improved by a well-defined bolus length, which was achieved by a modification version of Q2TIPS (quantitative imaging of perfusion using a single subtraction, second version with interleaved thin-slice TI1 periodic saturation): a series of saturation pulses was applied to both sides of the imaging slice at a certain time after the inversion. The dual navigator-gated technique was tested in eight volunteers. The measured renal cortex perfusion rates were between 191 and 378 mL/100 g/min in the renal cortex with a mean of 376 mL/100 g/min. The proposed technique may prove most beneficial for noncontrast-based renal perfusion quantification in young children and patients who may have difficulty holding their breath for prolonged periods or are sedated/anesthetized. Magn Reson Med 64:1352-1359, 2010. (C)2010 Wiley-Liss, Inc.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据