4.5 Article

Assessment of lipids in skeletal muscle by high-resolution spectroscopic imaging using fat as the internal standard: Comparison with water referenced spectroscopy

期刊

MAGNETIC RESONANCE IN MEDICINE
卷 59, 期 6, 页码 1259-1265

出版社

WILEY-BLACKWELL
DOI: 10.1002/mrm.21601

关键词

MR spectroscopy; spectroscopic imaging; muscular lipids; quantitation; external and internal fat reference; relaxation corrections

向作者/读者索取更多资源

The main purpose of the study was to compare proton (1H) single-voxel MR spectroscopy (MRS) with high-spatial-resolution spectroscopic imaging (MRSI) to determine the lipid content in human skeletal muscle. Unsuppressed water line was used as a concentration reference in the processing of singlevoxel spectra. The spectrum from yellow bone marrow with a 100% fat content and probe with the vegetable oil served as internal and external reference for high-spatial-resolution MRSI, respectively. Very good correlation was found between lipid concentrations measured by water referenced singlevoxel MRS and high-spatial-resolution MRSI with yellow bone marrow as the internal standard. Excellent correlation was found between total lipid concentrations estimated by high-spatial-resolution MRSI with vegetable oil as the external fat standard and yellow bone marrow as the internal reference. From comparison of single-voxel MRS and MRSI approaches, it follows that relaxation correction of the reference water and methylene fat line is inevitable in processing the standard single-voxel spectra. The high-resolution MRSI approach is recommended to avoid the problem of relaxation corrections and enables using vegetable oil as the external fat standard.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据