4.2 Article

Line-shape analysis of J-resolved NMR spectra: application to metabolomics and quantification of intensity errors from signal processing and high signal congestion

期刊

MAGNETIC RESONANCE IN CHEMISTRY
卷 47, 期 -, 页码 S86-S95

出版社

WILEY
DOI: 10.1002/mrc.2501

关键词

NMR; H-1; metabolomics; metabonomics; metabolic profiling; quantitation; SEM; deconvolution; lineshape; pJRES

资金

  1. EPSRC
  2. NERC [NER/J/S/2002/00618, NE/D002508/1]
  3. BBSRC [BB/F016298/1]
  4. Wellcome Trust
  5. Biotechnology and Biological Sciences Research Council [BB/F016298/1] Funding Source: researchfish
  6. Natural Environment Research Council [NE/D002508/1, NER/J/S/2002/00618] Funding Source: researchfish
  7. BBSRC [BB/F016298/1] Funding Source: UKRI
  8. NERC [NE/D002508/1] Funding Source: UKRI

向作者/读者索取更多资源

NMR spectroscopy remains one of the primary analytical approaches in metabolomics. Although 1D H-1 NMR spectroscopy is versatile, highly reproducible and currently the most widely used technique in NMR metabolomics, analysis of complex biological samples typically yields highly congested spectra with severely overlapping signals making unambiguous metabolite identification and quantification almost impossible. Consequently there is a growing use of 2D NMR methods, in particular H-1 J-resolved (JRES) spectroscopy, which spreads the high signal density into a second dimension. One potentially powerful method to deconvolute these JRES spectra, facilitating metabolite quantification, is via line-shape fitting. However, the mathematical functions describing the JRES NMR line-shape, in particular after applying apodisation functions and JRES specific processing, including tilting and symmetrisation, remain uncharacterised. Furthermore, possible quantitation errors arising from processing JRES spectra have not been evaluated, nor have the potentially adverse quantitative effects of overlapping dispersive tails of closely spaced signals in the 2D spectrum. Here we address these issues and evaluate the suitability of the JRES experiment for accurate complex mixture analysis. Specifically, we have examined changes in NMR line-shape and signal intensity after application of different apodisation functions (SINE and SEM) and JRES specific processing (tilting and symmetrising), comparing simulated and experimental data. We also report a significant quantitation error of up to 33%, dependent upon apodisation, due to overlap of the dispersive tails of closely spaced resonances. Finally, we have validated the use of these mathematical line-shape functions for metabolite quantitation of 2D JRES spectra, by comparison to corresponding 1D NMR datasets, using both gravimetrically-prepared chemically defined mixtures as well as biological tissue extracts. Copyright (C) 2009 John Wiley & Sons, Ltd.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.2
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据