4.4 Article

Can preoperative diffusion-weighted MRI predict postoperative hepatic insufficiency after curative resection of HBV-related hepatocellular carcinoma? A pilot study

期刊

MAGNETIC RESONANCE IMAGING
卷 28, 期 6, 页码 802-811

出版社

ELSEVIER SCIENCE INC
DOI: 10.1016/j.mri.2010.03.018

关键词

Fibrosis; Cirrhosis; Chronic hepatitis B; Hepatitis B virus; Diffusion-weighted magnetic resonance imaging; Apparent diffusion coefficient; Liver stiffness measurement; Transient elastography; Hepatectomy; Hepatocellular carcinoma

资金

  1. Ministry of Health, Welfare and Family Affairs, Republic of Korea [A050021]
  2. Brain Korea 21 Project for Medical Science

向作者/读者索取更多资源

Liver fibrosis determines the functional liver reserve. Several studies have reported that the apparent diffusion coefficient (ADC) values of diffusion-weighted magnetic resonance imaging (DW-MRI) can assess liver fibrosis. We investigated whether DW-MRI predicts postoperative hepatic insufficiency and liver fibrosis in patients with hepatitis B virus (HBV)-related hepatocellular carcinoma (HCC). Twenty-six patients with HBV-related HCC who received preoperative DW-MRI on a 3-T MRI system were enrolled between July and December 2008. ADC values were measured twice by two observers. Three b values were used: 50, 400 and 800 s/mm(2). Postoperative hepatic insufficiency was defined as persistent hyperbilirubinemia (total bilirubin level >5 mg/dl for more than 5 days after surgery) or postoperative death without other causes. The mean age (21 men and 5 women) was 51.4 years. Three patients experienced postoperative hepatic insufficiency, liver stiffness measurement predicted postoperative hepatic insufficiency, advanced fibrosis (F3-4), and cirrhosis significantly [area under the receiving operator characteristic curve (AUROC)=0.942, 0.771 and 0.818, respectively, with P=.047, 0.048 and 0.006, respectively]; ADC values of DW-MRI, however, did not (AUROC=0.797, 0.648 and 0.491, respectively, with P=.100, 0.313 and 0.938, respectively). Reliability of ADC values between right and left hepatic lobes (rho=0.868 and rho=0.910 in the first and second measures of Observer A; rho=0.865 and rho=0.831 in the first and second measures of Observer B) was high and the intra- and interobserver reliability (rho=0.958 in observer A and rho=0.977 in observer B; rho=0.929 in the first measure and rho=0.978 in the second measure between the two observers) were high. All reliability was significant (P<.001). Our results suggest that DW-MRI on a 3-T MRI system is not suitable for predicting postoperative hepatic insufficiency, advanced liver fibrosis, and cirrhosis in patients with HBV-related HCC, despite significantly high reliability. (C) 2010 Elsevier Inc. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据