4.4 Article

Development and initial evaluation of 7-T q-ball imaging of the human brain

期刊

MAGNETIC RESONANCE IMAGING
卷 26, 期 2, 页码 171-180

出版社

ELSEVIER SCIENCE INC
DOI: 10.1016/j.mri.2007.05.011

关键词

diffusion tenser imaging (DTI); high-field MR imaging; fiber tractography; high angular resolution diffusion imaging (HARDI); q-ball imaging (QBI); white matter

资金

  1. NIBIB NIH HHS [1 T32 EB001631-01A1, T32 EB001631] Funding Source: Medline
  2. NINDS NIH HHS [NS40117, R01 NS040117, R01 NS040117-05] Funding Source: Medline

向作者/读者索取更多资源

Diffusion tensor imaging (DTI) noninvasively depicts white matter connectivity in regions where the Gaussian model of diffusion is valid but yields inaccurate results in those where diffusion has a more complex distribution, such as fiber crossings. q-ball imaging (QBI) overcomes this limitation of DTI by more fully characterizing the angular dependence of intravoxel diffusion with larger numbers of diffusion-encoding directional measurements at higher diffusion-weighting factors (b values). However, the former technique results in longer acquisition times and the latter technique results in a lower signal-to-noise ratio (SNR). In this project, we developed specialized 7-T acquisition methods utilizing novel radiofrequency pulses, eight-channel parallel imaging EPI and high-order shimming with a phase-sensitive multichannel B-0 field map reconstruction. These methods were applied in initial healthy adult volunteer studies, which demonstrated the feasibility of performing 7-T QBI. Preliminary comparisons of 3 T with 7 T within supratentorial crossing white matter tracts documented a 79.5% SNR increase for b 3000 s/mm(2) (P=.0001) and a 38.6% SNR increase for b=6000 s/mm(2) (P=.015). With spherical harmonic reconstruction of the q-ball orientation distribution function at b=3000 s/mm(2), 7-T QBI allowed for accurate visualization of crossing fiber tracts with fewer diffusion-encoding acquisitions as compared with 3-T QBI. The improvement of 7-T QBI at b factors as high as 6000 s/mm(2) resulted in better angular resolution as compared with 3-T QBI for depicting fibers crossing at shallow angles. Although the increased susceptibility effects at 7 T caused problematic distortions near brain-air interfaces at the skull base and posterior fossa, these initial 7-T QBI studies demonstrated excellent quality in much of the supratentorial brain, with significant improvements as compared with 3-T acquisitions in the same individuals. (C) 2008 Elsevier Inc. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据