4.5 Article

Improving interface bonding of double-skinned CFST columns

期刊

MAGAZINE OF CONCRETE RESEARCH
卷 65, 期 20, 页码 1199-1211

出版社

ICE PUBLISHING
DOI: 10.1680/macr.13.00041

关键词

-

资金

  1. Research Grants Council of Hong Kong, China [HKU 712310E]
  2. University of Hong Kong [201111159038]

向作者/读者索取更多资源

It has been demonstrated that high-strength concrete (HSC) is able to improve the strength-to-weight ratio of reinforced concrete columns and maximise the usable areas of tall buildings. However, closely spaced transverse reinforcement needs to be installed to provide stronger confinement for averting brittle failure of HSC. To resolve the problem, double-skinned concrete-filled-steel-tubular (CFST) columns have been advocated, which eliminates the steel congestion problem for better concrete placing and reduces the concrete arching action thus providing a more uniform confining pressure. Despite these advantages, a major shortcoming of double-skinned CFST columns is that imperfect interface bonding occurs in the elastic stage that reduces elastic strength and stiffness. Thus, the authors proposed to adopt external confinement to restrict the lateral dilation of the outer tube of double-skinned CFST columns. To verify the effectiveness of the proposed external rings, a total of 20 double-skinned normal-and high-strength CFST columns were tested. From the test results, it was observed that the stiffness, axial load-carrying capacity and ductility of ring-confined double-skinned CFST columns were significantly higher than the unconfined columns.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据