4.7 Article

Quantitative Assessment of Inflammation in a Porcine Acute Terminal Ileitis Model: US with a Molecularly Targeted Contrast Agent

期刊

RADIOLOGY
卷 276, 期 3, 页码 809-817

出版社

RADIOLOGICAL SOC NORTH AMERICA
DOI: 10.1148/radiol.2015142478

关键词

-

资金

  1. Siemens
  2. Philips
  3. GE

向作者/读者索取更多资源

Purpose: To evaluate the feasibility and reproducibility of ultrasonography (US) performed with dual-selectin-targeted contrast agent microbubbles (MBs) for assessment of inflammation in a porcine acute terminal ileitis model, with histologic findings as a reference standard. Materials and Methods: The study had institutional Animal Care and Use Committee approval. Acute terminal ileitis was established in 19 pigs; four pigs served as control pigs. The ileum was imaged with clinical-grade dual P-and E-selectin-targeted MBs (MBSelectin) at increasing doses (0.5, 1.0, 2.5, 5.0, 10, and 20 x 10(8) MB per kilogram of body weight) and with control nontargeted MBs (MB Control). For reproducibility testing, examinations were repeated twice after the MB Selectin and MB Control injections. After imaging, scanned ileal segments were analyzed ex vivo both for inflammation grade (by using hematoxylin-eosin staining) and for expression of selectins (by using quantitative immunofluorescence analysis). Statistical analysis was performed by using the t test, intraclass correlation coefficients (ICCs), and Spearman correlation analysis. Results: Imaging signal increased linearly (P > .001) between a dose of 0.5 and a dose of 5.0 x 10(8) MB/kg and plateaued between a dose of 10 and a dose of 20 x 10(8) MB/kg. Imaging signals were reproducible (ICC = 0.70), and administration of MB Selectin in acute ileitis resulted in a significantly higher (P > .001) imaging signal compared with that in control ileum and MB Control. Ex vivo histologic grades of inflammation correlated well with in vivo US signal (r = 0.79), and expression levels of both P-selectin (37.4% +/- 14.7 [standard deviation] of vessels positive; P > .001) and E-selectin (31.2% +/- 25.7) in vessels in the bowel wall of segments with ileitis were higher than in control ileum (5.1% +/- 3.7 for P-selectin and 4.8% +/- 2.3 for E-selectin). Conclusion: Quantitative measurements of inflammation obtained by using dual-selectin-targeted US are reproducible and correlate well with the extent of inflammation at histologic examination in a porcine acute ileitis model as a next step toward clinical translation. (C) RSNA, 2015

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据